Start with the label you already have.
Keep the brand, complete catalog number, breaker-type list and date code together. The examples explain document fields, not how to open equipment.
On this page
- Quick answer
- What the box label shows (Square D samples)
- What the wiring diagram shows (Square D samples)
- Reading the catalog number: Square D's own guides
- Where recall notices say codes are printed
- Brand names as Eaton's classified list prints them
- Breaker features the makers describe
- Older brand names that appear in the documents
- What to bring to an electrician
- Sources
Quick answer
- Siemens' Murray instructions: "Refer to wiring diagram label on inside of load center door or cover for product ratings, acceptable components" [S10 p.1].
- Siemens' 2019 letter tells owners of pre-2002 Murray products to "refer to the wiring diagram affixed to the inside of the door of the loadcenter for the specific breaker types that are approved for that panel" [S1 p.1].
- Square D's current catalog shows two label samples, a "Box Label Sample" and a "Wiring Diagram Sample", for both QO and Homeline [Q7 p.33, p.34, p.60].
Illustrative layout. No real model or rating.
Keep the label and the document together.
Catalog numbers, breaker-type lists and dates are different fields. The actual label can use a different layout.
- Catalog number
Record the complete identifier, including suffixes. Square D label samples, pp.33–34, 60
- Printed breaker types
Keep the wiring-diagram label with the box label. Murray 4810366, p.1
- Date code
Preserve the exact code when comparing an applicable notice. CPSC QO notice
Original drawing and source annotations
The original drawing is schematic, not a product label, field measurement or installation instruction.
Open the original full-size SVGdoor of the panel" [C8]
Sources: Q7 = Square D catalog 1100CT0501 (06/2026) pp.33-34, 60 (label and wiring-diagram sample callouts); S10 = Murray/Siemens instructions 4810366 Rev. D pp.1-2; C10, C3, C8 =
CPSC recall notices (1988; 2010; 2022). The panel label and a licensed electrician decide what may be installed.

What the box label shows (Square D samples)
Square D's catalog annotates its QO and Homeline box label samples with these items [Q7 p.33, p.60]:
- "Number of circuits maximum" [Q7 p.33, p.60]
- "Enclosure catalog number" [Q7 p.33, p.60]
- "Catalog number of covers; flush or surface" [Q7 p.33, p.60]
- "See load center interior for the catalog number" [Q7 p.33, p.60]
- "Voltage ratings" and "Amperage rating" [Q7 p.33, p.60]
- "Wire range for lug torque data" (QO sample) and "Wire range for lug torque data table" (Homeline sample) [Q7 p.33, p.60]
- "Short circuit ratings" and "Short circuit ratings and additional or replacement circuit breakers" [Q7 p.33, p.60]
- "UL manifest", "Date code", "Plant code", "Label part number" and "Manufacturer trademark" [Q7 p.33, p.60]
The QO sample also lists "CE if required" and "NOM if required" [Q7 p.33].
What the wiring diagram shows (Square D samples)
The wiring diagram samples carry these callouts [Q7 p.34, p.60]:
- "Square D circuit breakers that may be used in this load center" [Q7 p.34, p.60]
- "Service Equipment marking. Unused neutral branch terminal for equipment grounding, service equipment application only." [Q7 p.34, p.60]
- "Installation of back-fed main circuit breaker and required kit" [Q7 p.34, p.60]
- "Load center accessories" [Q7 p.34, p.60]
- "Alternate wiring diagram for main circuit breaker or main lug" [Q7 p.34, p.60]
On Murray load centers, Siemens' instruction sheet says "Applicable accessories are listed on the wiring diagram label" [S10 p.2].
Reading the catalog number: Square D's own guides
Square D publishes a position-by-position guide for its load center catalog numbers [Q7 p.6, p.46].
| Position | QO example "QO 1 30 L 200 P G C CP" [Q7 p.6] | Homeline example "HOM 8 16 L 125 P G C CP" [Q7 p.46] |
|---|---|---|
| 1 – Brand | "QO = QO" | "HOM = Homeline" [Q7 p.6, p.46] |
| 2 | Phases: "Blank or 1 = Single-phase", "3 = Three-phase" | Spaces: "Maximum number of full-size single-pole circuit breaker spaces." [Q7 p.6, p.46] |
| 3 | Spaces: "Maximum number of full-size single-pole circuit breaker spaces." | Circuits: printed with the same wording as Position 2 [Q7 p.6, p.46] |
| 4 – Mains type | "M = Main Circuit Breaker", "L = Main Lugs", "DM = Dual Mains", plus MS and MQ | "M = Main Circuit Breaker", "L = Main Lugs" [Q7 p.6, p.46] |
| 5 | Mains rating (amperes) | Mains rating (amp) [Q7 p.6, p.46] |
| 6 – Construction | "FT = Feed Through", "P = Plug on Neutral", "Q = Qwik-Grip", "WG = Wide Gutter" | "FT = Feed Through", "P = Plug on Neutral", "Q = Qwik-Grip" [Q7 p.6, p.46] |
| 7 – Ground bar | "G = Included", "T = Factory Installed" | "G = Included", "T = Factory Installed" [Q7 p.6, p.46] |
| 8 – Cover | "C = Combination Cover (included)", "F = Flush Cover", "S = Surface Cover", "R = Rainproof", "B = Hub ready" | Same five codes [Q7 p.6, p.46] |
| 9 – Other | "CP = Consumer Products", "CU = Copper bus", "VP = Value pack" | Adds "EP = Service upgrade panel" [Q7 p.6, p.46] |
Both guides add a note under Position 3: "Number of maximum circuits is specified in the end package label." [Q7 p.6, p.46]
Where recall notices say codes are printed
CPSC notices give label locations for specific products [C2] [C3] [C7] [C8] [C10] [C17]:
- I-T-E (Siemens), 1986–87 load centers. "a five-digit code marked on the top of the wiring diagram label inside the door which is opened to reset the circuit breakers" [C10].
- Siemens and Murray, 2010 [C3]:
- Square D QO Plug-on-Neutral, 2022 [C8]:
- Challenger, 1988. "If the name 'Challenger' is embossed on the front of the panel (on the door handle) and/or on the label on the back of the panel/door, that panel may contain circuit breakers requiring replacement." [C2]
- Square D AFCI, 2004. The date codes are "stamped in red on the breaker label located just above the wiring terminal" [C7].
- Eaton meter breakers, 2014. "The catalog number is located on the unit's packaging." [C17]
Brand names as Eaton's classified list prints them
Eaton's list IL00304001Y groups panel catalog numbers under maker headings. On the rendered pages they read [E1 pp.2–3, 5–10]:
- "Square D" [E1]
- "General Electric" [E1]
- "GE" [E1 p.3]
- "Siemens" [E1]
- "Murray" [E1]
- "ITE/Siemens" [E1]
- "Crouse-Hinds/Murray" [E1]
- "Thomas & Betts" [E1]
Our transcription of these pages has 1,539 catalog-number entries, 1,523 of them unique [E1 pp.2–3, 5–10].
Breaker features the makers describe
Compare a printed dimension, not an installation permission. Equal width does not establish a listed or classified combination.
Original drawing and source annotations
The original drawing is schematic, not a product label, field measurement or installation instruction.
Open the original full-size SVG"½" THQP"; ABB not accepting new orders as of October 2, 2024
Sources: E5 Eaton Residential Product Guide MZ00400002E p.5, p.8; K5 Eaton KB 000015509; E12 Eaton CA08100002E (2022) p.103; E1 Eaton IL00304001Y p.1; Q6 Square D 0730CT9801 p.3;
Q7 Square D 1100CT0501 pp.45, 67; S9 Siemens SPEEDFAX SF-17 pp.1, 47; S4 Siemens QD brochure p.1; G1 ABB THQP notice (June 28, 2024) p.1. The panel label governs.
Eaton's residential guide compares its two families side by side [E5 p.5]:
- Type CH: "¾-inch wide", "Trips to OFF position", "Sandalwood handle". [E5 p.5]
- Type BR: "1-inch wide", "Trips to CENTER position", "Black handle". [E5 p.5]
Eaton's knowledge article gives the CH handle colour as "tan" [K5].
Square D's catalog compares its two families [Q7 p.67]:
- QO: "QO 3/4 in. breakers feature Visi-Trip trip to center position". [Q7 p.67]
- Homeline: "Homeline 1 in. circuit breakers trip to center position". [Q7 p.67]
Square D describes Visi-Trip this way: "When the circuit breaker has tripped, the handle assumes a center position and the red Visi-Trip indicator appears in a window in the circuit breaker case." [Q6 p.3]
Siemens' catalog headings read "Type QP, 1" Breakers" and "Type QD, 3/4" Breakers" [S9 p.1]. ABB refers to "the standard 1” THQL circuit breakers" and to "½” THQP circuit breakers" [G1 p.1].
Older brand names that appear in the documents
- Eaton: "Eaton has the largest installed base of residential circuit breakers, which includes legacy brands such as Westinghouse, Challenger, Bryant, and our current Type CH & Type BR designs." [E5 p.4]
- Murray: Siemens wrote in 2019 that "The Murray brand of circuit breakers is being phased out and replaced by equivalent Siemens products." [S1 p.1]
- I-T-E: CPSC's 1988 notice describes "I-T-E brand circuit-breaker boxes (load centers)" of "the Circuit Protection Division of Siemens Energy & Automation, Inc." [C10]
- GE: a 2004 CPSC notice names "GE Consumer & Industrial" as a manufacturer of the recalled TSLR1220CSAL meter load center [C13]. ABB's 2024 notice covers THQP and THQL breakers [G1 p.1].
What to bring to an electrician
- The box label and wiring diagram label items listed above [Q7 p.33, p.34, p.60].
- The panel catalog number and the date code [C8] [C10].
- Any Square D statement that applies: Square D says its QO and Homeline load centers "are UL tested, listed, and labeled to accept ONLY Square D circuit breakers" [Q1].
- Any CPSC notice whose identifiers match yours [C3] [C7] [C8] [C10].
Sources
| ID | Publisher | Document / version | Link | Kind |
|---|---|---|---|---|
| E1 | Eaton | IL00304001Y, visible imprint "Revised September 2024" (p.10); hidden text layers also contain "Revised May 2024" and REV. 24/27 markers; PDF mod 2025-06-05, 10 pp | link | primary |
| E5 | Eaton | MZ00400002E (PDF mod 2025-06-13), 44 pp | link | primary |
| K5 | Eaton Knowledge Hub | Article 000015509 "Major differences between BR and CH breakers", printed 2026-11-15 (right edge of table truncated in print) | link | primary |
| S1 | Siemens Industry (copy linked from the Siemens Sandy FAQ page S3) | letter dated 2019-09-05, 2 pp | link | primary-mirror |
| S9 | Siemens Industry | SPEEDFAX Section 1 Load Centers & Circuit Breakers, web edition SF-17-Sect-01-ALL (PDF created 2025-01-29; pages individually revised 2020-03 to 2025-01), 56 pp | link | primary |
| S10 | Siemens Industry / Murray Electrical Products | Installation instructions "Single Phase Load Centers 12 thru 42 Circuits", 4810366 Rev. D, (c) 2009 (PDF created 2018-01-05), 4 pp image-only (OCR in raw/ocr/) | link | primary |
| Q1 | Schneider Electric / Square D | FAQ FA109246, fetched 2026-11-15 | link | primary |
| Q6 | Schneider Electric / Square D | Catalog 0730CT9801R1/08 "QO and QOB Miniature Circuit Breakers", Class 730, 07/2008, 40 pp (download.schneider-electric.com), captured 2026-11-15 | link | primary |
| Q7 | Schneider Electric / Square D | Catalog 1100CT0501 "Square D QO and Homeline Load Centers and Enclosures", 06/2026 (footer Rev.03), 88 pp; printed page = PDF page; captured 2026-11-15 | link | primary |
| G1 | ABB Electrification US | LCM announcement 2024-06-28, ABB document 1TQC114500E0003, 3 pp | link | primary |
| C2 | U.S. CPSC | recall 1988-11-12 | link | primary |
| C3 | U.S. CPSC | recall 2010-09-23 | link | primary |
| C7 | U.S. CPSC | recall 2004-11-03 | link | primary |
| C8 | U.S. CPSC | recall 2022-06-16 | link | primary |
| C10 | U.S. CPSC | cpsc.gov recall web page, Recall Date November 01, 1988, recall number 88-091; printed to PDF in browser 2026-11-16, 4 pp | link | primary |
| C13 | U.S. CPSC | cpsc.gov recall web page, Recall Date November 19, 2004, recall number 05-515; printed to PDF in browser 2026-11-16, 4 pp | link | primary |
| C17 | U.S. CPSC | cpsc.gov recall web page, Recall Date December 02, 2014, recall number 15-710; printed to PDF in browser 2026-11-16, 4 pp | link | primary |
All documents fetched 2026-11-15 or 2026-11-16 and archived with SHA256 (see SOURCE-LIBRARY.csv). Kind: primary = issued by the manufacturer/agency; primary-mirror = manufacturer document hosted by a third party; primary (vendor) = issued by the maker of the replacement product described.
Related reference photographs

Photo credit and licence
"Frank Adam electrical panel label from 1946.jpg" by Circacies, licensed CC BY-SA 4.0 (https://creativecommons.org/licenses/by-sa/4.0), via Wikimedia Commons: https://commons.wikimedia.org/wiki/File:Frank_Adam_electrical_panel_label_from_1946.jpg Resized for the web.
Original Commons file and licenceKeep the reference with your question.
Retain the exact identifier, document revision, page and unresolved conditions. The lookup covers only one Eaton list; a result is not an equipment or installation assessment.
Search Eaton’s document Record a source discrepancy