All references

Murray: keep the date with the series.

Read the Siemens letters alongside the panel’s wiring-diagram label. The published cross-reference tables are shown separately where their wording differs.

Quick answer

Siemens, which announced the phase-out of the Murray brand in 2019 [S2 p.1], wrote in September 2019 that Murray Meter Combo, EQ Small Circuit and Rock Solid load centers manufactured after January 2002 may use Siemens breakers, and that Siemens breakers are UL listed for use with those products [S1 p.1]. For Murray products made before January 2002, the letter says to use the breaker types on the wiring diagram inside the loadcenter door [S1 p.1]. Separately, Eaton lists certain Murray panelboards and meter centers for its UL Classified Type CL breakers [E1 pp.3, 9].

Dates printed in the documents

Left: product and brand documents. Right: CPSC actions. Only dates stated in the cited primary documents; no ownership history is inferred.

  1. 1968

    E12 p.78; S9 p.45

    Non-CTL replacement breakers: "For replacement in enclosures manufactured

    prior to 1968 with unnotched stabs" (Eaton); "panels manufactured before 1968"

    (Siemens)

  2. 1979

    C1

    FPE: CPSC notice refers to breakers "manufactured before Reliance acquired FPE

    in 1979"

  3. 1983

    C1

    Mar 3, 1983: CPSC closes its FPE Stab-lok investigation (2011 note: "without

    making a determination as to the safety" of the breakers)

  4. 1987

    C10

    Sept 1986-May 1987: I-T-E load centers installed in this period covered by

    Siemens' free inspection program (notice issued Nov 1, 1988)

  5. 1988

    C11

    Apr 13, 1988: Square D Series 1 two-pole GFCI breakers - free replacement

    program

  6. 1988

    C2

    Nov 12, 1988: Challenger type HAGF-15 / HAGF-20 GFCI breakers - recall

  7. 1998

    C4

    Oct 7, 1998: Siemens / Murray 2-pole GFCI breakers - recall

  8. 2002

    S1 p.1

    After January 2002: Murray Meter Combo, EQ Small Circuit and

    Rock Solid load centers may use Siemens breakers (S1 p.1).

  9. 2003

    C16

    "authentic Square D circuit breakers manufactured prior to 2003 did not have

    white paint on the amperage numbers"

  10. 2004

    C7; C13

    Nov 3, 2004: Square D QO / Homeline AFCI breakers; Nov 19, 2004: Midwest / GE

    meter load centers

  11. 2006

    C6, C14, C15, C16, C5

    Nov 2006-Aug 2010: five recalls of counterfeit "Square D" breakers by

    distributors

  12. 2010

    C3

    Sept 23, 2010: Siemens / Murray 15-50 A breakers, load centers and meter

    combos (spring clip)

  13. 2014

    C17

    Dec 2, 2014: Eaton MBED3042 residential meter breakers

  14. 2019

    S1 p.1

    Sept 5, 2019: Siemens letter - "The Murray brand of circuit breakers is being

    phased out"

  15. 2022

    C8

    Jun 16, 2022: Square D QO Plug-on-Neutral load centers - recall

  16. 2024

    G1 p.1

    Oct 2, 2024: ABB stops accepting new orders for 1/2" THQP breakers

    Eaton: "Eaton has the largest installed base of residential circuit breakers, which includes legacy brands such as Westinghouse, Challenger, Bryant, and our current Type CH & Type BR

    designs." (E5 p.4)

Original drawing and source annotations

The original drawing is schematic, not a product label, field measurement or installation instruction.

Open the original full-size SVG

designs." (E5 p.4)

Sources: E12 Eaton CA08100002E p.78; S9 Siemens SPEEDFAX p.45; C1-C17 CPSC recall notices; S1 Siemens letter 2019-09-05 p.1; G1 ABB notice 2024-06-28 p.1; E5 Eaton MZ00400002E p.4.

Dates are those printed in each notice.

A blue archive binder, abstract document sheets and magnifier beside a closed generic cover.
AI-generated concept illustration. Keep the document edition and equipment date separate. The abstract marks are not a wiring diagram, real document or verified equipment detail. Not technical evidence.

Murray → Siemens cross-reference (from Siemens' 2019 substitution letter)

Type (as printed in the letter)MurraySiemensSource
Combination Type AFCIMP-AT2 / MP-HAT2 / MP-MAT2QAF2 / QAFH2 / HQAF2[S1 p.2]
Combination Type AFCIMP-AT2 / MP-HAT2QAF / QAFH[S1 p.2]
Branch-Feeder AFCIMP-AT2 / MP-HAT2 / MP-MAT2QAF2 / QAFH2 / HQAF2[S1 p.2]
Dual Function AFCI/GFCIMP-GAT2 / MP-HGAT2 / MP-MGAT2QFGA2 / QFGAH2 / HQFGA2[S1 p.2]
Ground-Fault Circuit Interrupters (Class A - 5mA)MP-GT / MP-HGTQPF2 / QPHF2 / HQPF2[S1 p.2]
Ground-Fault Circuit Interrupters (Class A - 5mA)MP-GT / MP-HGTQPF / QPHF[S1 p.2]
Ground Fault Equipment Protection (30mA)MP-ET / MP-HETQE / QEH[S1 p.2]
Full Size (1" per Pole) with INSTA-WIREMP-T / MP-HT / MP-MTQP / QPH / HQP[S1 p.2]
Duplex, Triplex and Quadplex Plug-in BreakersMH-TQT[S1 p.2]
Special Application BreakersMP-T / MGQP / QG[S1 p.2]
Type MSQ, 3/4 Inch Plug-In BreakersMSQQD[S1 p.2]
Main and Branch Circuit BreakersMD-T / MD-HT / MD-MTQN / QNH / HQN[S1 p.2]
Main and Branch Circuit BreakersM1 / M2EQ8681 / EQ8682 / EQ8693 / EQ8695 / EQ8696[S1 p.2]
Main and Branch Circuit BreakersED-AQPJ[S1 p.2]
Main and Branch Circuit BreakersMPP / MPP-HT / MPP-MT / MPP-PTQPP / QPPH / HQPH / HQPP / HQPPH[S1 p.2]
Circuit Breaker and Surge Protective Device (SPD)MSAQSA[S1 p.2]

Source: [S1 p.2]. The copies of S1 and S2 used here are the letters linked from Siemens' "Murray Phase-out" FAQ page ("Murray Products - Phase-out Letter", "Murray Products - Substitution Letter") [S3]. The letter also lists EQ load-center cross references, not reproduced here [S1 p.2]. On p.1 it names "All Murray Meter Combo Load Centers, EQ Small Circuit Load Centers, and Rock Solid Load Centers manufactured after January 2002", and for products made before that date it says to "refer to the wiring diagram affixed to the inside of the door of the loadcenter" [S1 p.1].

UL letter on Murray breaker types in Siemens equipment (2020)

Siemens' support site hosts a UL LLC letter to Siemens Industry dated 2020-02-11, subject "Murray Breaker Types Used in Siemens Equipment" [S11 p.1].

  • "At Siemen's request, UL LLC reviewed the documentation associated with Murray Circuit Breakers listed below and compared this documentation to the existing Siemens Circuit Breakers listed below." [S11 p.1]
  • "These breakers are identical in construction except for type and catalog number." [S11 p.1]
  • "The Murray circuit breaker types, manufactured by Siemens, may be used or are suitable replacements in Siemens panelboards, or other products, designating the use of the Siemens circuit breaker types." [S11 p.2]
  • "This comparison for replacement breakers includes evaluation as part of a Series Rating." [S11 p.2]
Breaker Types (Marked on Siemens Panelboard)Murray Breaker TypeSource
QAF2 / QAFH2 / HQAF2MP-AT2 / MP-HAT2 / MP-MAT2[S11 p.1]
QAF / QAFHMP-AT / MP-HAT[S11 p.1]
QAF2 / QAFH2 / HQAF2MP-AT2 / MP-HAT2 / MP-MAT2[S11 p.1]
QFGA2 / QFGAH2 / HQFGA2MP-GAT2 / MP-HGAT2 / MP-MGAT2[S11 p.1]
QPMP-T[S11 p.1]
QTMH-T[S11 p.1]
QPMP-T[S11 p.1]
QPP / QPPH / HQPP / HQPPHMPP-T / MPP-HT / MPP-MT / MPP-PT[S11 p.1]
QPF2, QPHF2, HQPF2MP-GT2, MP-HGT2, MP-MGT2[S11 p.1]
QE2, QEH22MP-ET2, MP-HET2[S11 p.1]

The table is reproduced row by row as printed, including the repeated QAF2 and QP rows and "QEH22" [S11 p.1].

Where the two documents print pairings differently (both shown as printed):

UL letter 2020 [S11 p.1]Siemens letter 2019 [S1 p.2]
QAF / QAFH ↔ MP-AT / MP-HATMP-AT2/MP-HAT2 → QAF/QAFH
QPF2, QPHF2, HQPF2 ↔ MP-GT2, MP-HGT2, MP-MGT2MP-GT/MP-HGT → QPF2/QPHF2/HQPF2
QE2, QEH22 ↔ MP-ET2, MP-HET2MP-ET/MP-HET → QE/QEH
QPP / QPPH / HQPP / HQPPH ↔ MPP-T / MPP-HT / MPP-MT / MPP-PTMPP/MPP-HT/MPP-MT/MPP-PT → QPP/QPPH/HQPH/HQPP/HQPPH

Murray compatibility table

PanelEraBreaker familySourceDocument wording
Murray Meter Combo, EQ Small Circuit, Rock Solid load centersmanufactured after January 2002Siemens equivalents (table above)[S1 p.1–2]S1 p.1: "All Murray Meter Combo Load Centers, EQ Small Circuit Load Centers, and Rock Solid Load Centers manufactured after January 2002 may use Siemens brand circuit breakers." "Siemens brand circuit breakers are UL listed for use with the Murray products manufactured after that date."
Murray productsmanufactured prior to January 2002Breaker types on the door wiring diagram[S1 p.1]S1 p.1: "For Murray products manufactured prior to January 2002, please refer to the wiring diagram affixed to the inside of the door of the loadcenter for the specific breaker types that are approved for that panel."
Murray panelboards and meter centers on Eaton's listlegacyEaton CL (replaces MP115–MP250); CL115GFT–CL130GFT (replaces MP115GF–MP130GF); CL115AF–CL120AF (replaces MP115AF–MP120AF); CL115CAF–CL120CAF, CLCAF115–CLCAF120, CLAF115 and CLAF120 (replace MP115AFC–MP120AFC); CLDF115–CLDF120 (replaces MP115DF–MP120DF)[E1 p.4; panel lists pp.3, 9] [E3 p.3]E1 p.1: "Single-Phase, 3-Wire, 120/240 V~", "Max. Available Short Circuit Current 10 kAIC"; E1 p.4 DANGER: "Do not use in series rated systems with those panelboards shown in this compatibility list" [E1 p.1, p.4]
Siemens panelboards, or other products, designating the Siemens types (UL wording)UL letter dated 2020-02-11Murray types in the UL table above[S11 pp.1–2]S11 p.2: "The Murray circuit breaker types, manufactured by Siemens, may be used or are suitable replacements in Siemens panelboards, or other products, designating the use of the Siemens circuit breaker types."
Specific Square D loadcenterslegacyMurray MSQ (MQ115–MQ160; MQ215–MQ260)[S6 PDF p.61] [S1 p.1–2]S6 p.61: "Murray Type MSQ circuit breakers are UL Classified for use in specific Square D® load-centers in place of Square D® Type QO® circuit breakers." S1 p.1: "The Murray brand of circuit breakers is being phased out and replaced by equivalent Siemens products." S1 p.2 maps MSQ → QD

How to read a Murray panel label

  • Find the wiring diagram on the inside of the door. Siemens points pre-2002 owners to it [S1 p.1]. It names the approved breaker types. Murray's own instruction sheet says the same label lists ratings and acceptable components, and that branch breakers must be the type the label requires [S10 pp.1–2].
  • Find the catalog number and any manufacturing date. The January 2002 cut-off depends on the manufacture date [S1 p.1].
  • Check whether the panel is a Meter Combo, EQ Small Circuit or Rock Solid model. Only those lines are named in the letter [S1 p.1].
Where your panel's own documents put the key facts

Keep the label and the document together.

Catalog numbers, breaker-type lists and dates are different fields. The actual label can use a different layout.

  1. Catalog number

    Record the complete identifier, including suffixes. Square D label samples, pp.33–34, 60

  2. Printed breaker types

    Keep the wiring-diagram label with the box label. Murray 4810366, p.1

  3. Date code

    Preserve the exact code when comparing an applicable notice. CPSC QO notice

Original drawing and source annotations

The original drawing is schematic, not a product label, field measurement or installation instruction.

Open the original full-size SVG

door of the panel" [C8]

Sources: Q7 = Square D catalog 1100CT0501 (06/2026) pp.33-34, 60 (label and wiring-diagram sample callouts); S10 = Murray/Siemens instructions 4810366 Rev. D pp.1-2; C10, C3, C8 =

CPSC recall notices (1988; 2010; 2022). The panel label and a licensed electrician decide what may be installed.

Era and series history

WhenEventSource
Before 1968Some Murray space-saver breakers marked "Non-CTL… for replacement use only in panels manufactured before 1968"[S6 PDF p.58]
March 1996 – April 1998Sale period of Siemens/Murray 2-pole GFCI breakers later recalled[C4]
January 2002By its letter of September 2019: "Siemens has updated the UL listing of Murray Rock Solid Load Centers, Meter Combos and Small Circuit Load Centers manufactured after January of 2002 to accept Siemens breakers."[S2 p.1]
June – August 2010Siemens & Murray breakers with date codes 0610/0710 recalled[C3]
11 February 2020UL LLC letter to Siemens: "Murray Breaker Types Used in Siemens Equipment"[S11 p.1]
December 2019"Murray Mini Circuit Breaker", "Murray Electronic Breakers", "Meter Combos", "EQ Small Circuit Load Centers"[S2 p.1]
Summer 2020"Murray Rock Solid Load Centers"[S2 p.1]
Fall 2020Murray sockets phased out[S2 p.1]

Siemens wrote that Siemens and Murray meter combos, EQ Small Circuit load centers and breakers "are typically identical in construction and only differ in labeling" [S2 p.1].

Recalls and counterfeits

  • CPSC recall 10-354 (2010).
    • Murray catalog numbers MP115, MP115U, MP120, MP130, MP215, MP230, MP230U and MP250 with date code 0610 or 0710, alongside Siemens Q-type breakers [C3].
    • About 2.2 million units in total [C3].
    • Hazard: a spring clip can break, causing loss of connection force, overheating and arcing [C3].
  • 1998 recall. About 144,000 Siemens- or Murray-branded 2-pole GFCI breakers. The sticker reads "2 Pole Unit" [C4].

Common confusions

  • "Every Murray panel can take Siemens breakers." Siemens' letter names Meter Combo, EQ Small Circuit and Rock Solid load centers "manufactured after January 2002" [S1 p.1].
  • "Eaton BR is the Murray replacement." Eaton's Classified line for listed Murray panels is CL [E1] [E3 p.3]. Eaton describes BR as the replacement for Westinghouse, Challenger and Bryant loadcenters [E5 PDF p.5].
  • "Murray breakers are gone, so the panel must be replaced." Siemens equivalents are documented for the post-2002 lines [S1 p.1–2]. For older panels, the door label decides.

FAQ

Are Siemens and Murray breakers interchangeable? For Murray Meter Combo, EQ Small Circuit and Rock Solid load centers made after January 2002, Siemens says Siemens breakers may be used and are UL listed for them [S1 p.1]. For older Murray panels, follow the door wiring diagram [S1 p.1].

What breakers are compatible with Murray MP-T? Siemens' cross-reference maps MP-T / MP-HT / MP-MT to QP / QPH / HQP [S1 p.2]. Siemens' letter: "Siemens brand circuit breakers are UL listed for use with the Murray products manufactured after that date"; for products made before January 2002 it refers to "the wiring diagram affixed to the inside of the door of the loadcenter" [S1 p.1].

Can I use an Eaton CL breaker in a Murray panel? Only if the Murray panelboard or meter center catalog number is on Eaton's list IL00304001Y [E1 pp.3, 9], within 120/240 V and 10 kA [U1 item 97].

Were Murray breakers recalled? Two CPSC recalls on record name Murray breakers: certain 2-pole GFCI breakers sold 1996–1998 [C4], and certain breakers dated 0610/0710 in 2010 [C3].

Do they still make Murray breakers? Siemens phased out Murray breakers in December 2019 [S2 p.1].

Is Murray the same as Siemens? Murray's instruction sheet prints "Murray Electrical Products" and "Siemens Industry, Inc." in its footer [S10 p.1], and Siemens' September 2019 letter sets out the Murray phase-out dates [S2 p.1]. Siemens says Siemens and Murray meter combos, EQ Small Circuit load centers and breakers are "typically identical in construction and only differ in labeling" [S2 p.1]. Siemens' substitution letter names Murray products "manufactured after January 2002" [S1 p.1].

Are Murray and Square D breakers interchangeable? Murray made a ¾-inch Type MSQ breaker that Siemens' 2017 catalog describes as UL Classified for use in specific Square D load centers in place of Square D QO breakers [S6 PDF p.61]. Murray breakers were phased out in 2019 [S2 p.1], and Siemens maps MSQ to its Type QD [S1 p.2]. Square D says only Square D breakers keep its QO and Homeline listing [Q1].

Sources

IDPublisherDocument / versionLinkKind
E1EatonIL00304001Y, visible imprint "Revised September 2024" (p.10); hidden text layers also contain "Revised May 2024" and REV. 24/27 markers; PDF mod 2025-06-05, 10 pplinkprimary
E3EatonBR003051EN (URL br003034en), July 2026, 4 pplinkprimary
E5EatonMZ00400002E (PDF mod 2025-06-13), 44 pplinkprimary
S1Siemens Industry (copy linked from the Siemens Sandy FAQ page S3)letter dated 2019-09-05, 2 pplinkprimary-mirror
S2Siemens Industry (copy linked from the Siemens Sandy FAQ page S3)letter dated 2019-09-05, 2 pplinkprimary-mirror
S3Siemens (sandy.compas.siemens-info.com FAQ)web FAQ, fetched 2026-11-15linkprimary
S6Siemens IndustrySPEEDFAX 2017 Section 1 Load Centers & Circuit Breakers (PDF mod 2020-02-13), 66 pplinkprimary
S10Siemens Industry / Murray Electrical ProductsInstallation instructions "Single Phase Load Centers 12 thru 42 Circuits", 4810366 Rev. D, (c) 2009 (PDF created 2018-01-05), 4 pp image-only (OCR in raw/ocr/)linkprimary
S11UL LLC (letter to Siemens Industry, Inc.; hosted on Siemens Industry Online Support)UL LLC letter dated 2020-02-11, subject "Murray Breaker Types Used in Siemens Equipment", Our Reference File E82615, E82617, E160869 and E468786, Project Number 4789379155; 2 pp image-only (OCR and visual check in raw/ocr/); captured 2026-11-16linkprimary
Q1Schneider Electric / Square DFAQ FA109246, fetched 2026-11-15linkprimary
U1UL SolutionsMCCB Marking and Application Guide (web), fetched 2026-11-15linkprimary
C3U.S. CPSCrecall 2010-09-23linkprimary
C4U.S. CPSCrecall 1998-10-07linkprimary

All documents fetched 2026-11-15 or 2026-11-16 and archived with SHA256 (see SOURCE-LIBRARY.csv). Kind: primary = issued by the manufacturer/agency; primary-mirror = manufacturer document hosted by a third party.

Murray to Siemens: what Siemens' 2019 letter says

Cross reference reproduced as text from the letter's table (S1 p.2). The letter names Murray products manufactured after January 2002 (S1 p.1).

After January 2002: "All Murray Meter Combo Load Centers, EQ Small Circuit Load Centers, and Rock Solid Load Centers manufactured after January 2002 may use Siemens brand circuit breakers." (S1 p.1) Before January 2002: "please refer to the wiring diagram affixed to the inside of the door of the loadcenter for the specific breaker types that are approved for that panel." (S1 p.1)

Type in the letter
Combination Type AFCI
Murray
MP-AT2 / MP-HAT2 / MP-MAT2
Siemens
QAF2 / QAFH2 / HQAF2
Type in the letter
Combination Type AFCI
Murray
MP-AT2 / MP-HAT2
Siemens
QAF / QAFH
Type in the letter
Branch-Feeder AFCI
Murray
MP-AT2 / MP-HAT2 / MP-MAT2
Siemens
QAF2 / QAFH2 / HQAF2
Type in the letter
Dual Function AFCI/GFCI
Murray
MP-GAT2 / MP-HGAT2 / MP-MGAT2
Siemens
QFGA2 / QFGAH2 / HQFGA2
Type in the letter
Ground-Fault Circuit Interrupters (Class A - 5mA)
Murray
MP-GT / MP-HGT
Siemens
QPF2 / QPHF2 / HQPF2
Type in the letter
Ground-Fault Circuit Interrupters (Class A - 5mA)
Murray
MP-GT / MP-HGT
Siemens
QPF / QPHF
Type in the letter
Ground Fault Equipment Protection (30mA)
Murray
MP-ET / MP-HET
Siemens
QE / QEH
Type in the letter
Ground Fault Equipment Protection (30mA)
Murray
MP-ET / MP-HET
Siemens
QE / QEH
Type in the letter
Full Size (1" per Pole) with INSTA-WIRE
Murray
MP-T / MP-HT / MP-MT
Siemens
QP / QPH / HQP
Type in the letter
Duplex, Triplex and Quadplex Plug-in Breakers
Murray
MH-T
Siemens
QT
Type in the letter
Special Application Breakers
Murray
MP-T / MG
Siemens
QP / QG
Type in the letter
Type MSQ, 3/4 Inch Plug-In Breakers
Murray
MSQ
Siemens
QD
Type in the letter
Main and Branch Circuit Breakers
Murray
MD-T / MD-HT / MD-MT
Siemens
QN / QNH / HQN
Type in the letter
Main and Branch Circuit Breakers
Murray
M1 / M2
Siemens
EQ8681 / EQ8682 / EQ8693 / EQ8695 / EQ8696
Type in the letter
Main and Branch Circuit Breakers
Murray
ED-A
Siemens
QPJ
Type in the letter
Main and Branch Circuit Breakers
Murray
MPP / MPP-HT / MPP-MT / MPP-PT
Siemens
QPP / QPPH / HQPH / HQPP / HQPPH
Type in the letter
Circuit Breaker and Surge Protective Device (SPD)
Murray
MSA
Siemens
QSA

Original letter, pp.1–2 · Compare the separately printed UL letter: S11

Original drawing and source annotations

The original drawing is schematic, not a product label, field measurement or installation instruction.

Open the original full-size SVG

QSA

Sources: S1 Siemens Industry letter "To whom it may concern", September 5, 2019, pp.1-2 (copy linked from the Siemens Sandy FAQ page and hosted on compas-training-

videos.s3.amazonaws.com; primary-mirror). The letter also lists EQ load-center cross references (not shown).

Keep the reference with your question.

Retain the exact identifier, document revision, page and unresolved conditions. The lookup covers only one Eaton list; a result is not an equipment or installation assessment.