All references

Siemens: start with the panel family.

Keep QP, QD, legacy family names and the applicable document separate. Use the source pages to see exactly which statement applies.

Quick answer

Siemens' catalog lists Type QP, QPH and HQP breakers with 10,000, 22,000 and 65,000 A interrupting ratings [S6 PDF p.36]; Siemens' Murray cross-reference places QP / QPH / HQP in the row "Full Size (1" per Pole) with INSTA-WIRE" [S1 p.2]. UL's public Product iQ entry for Siemens (file DIVQ.E82615) lists Types QP, QT, QD, QAF2, HQP and others as UL listed models [P3]. Eaton's list IL00304001Y prints Siemens meter centers under Type CL headings [E1 p.3] and ITE/Siemens panelboards on pp.5–7, where the one Eaton type heading printed is "CLDF115, CLDF120" [E1 p.5], and its knowledge base names ITE/Siemens among the loadcenters it offers CL replacements for [K4]. Siemens' own Classified line, Type QD, goes the other way: it is for specific Square D load centers [S6 PDF p.39].

Residential breaker families: width and trip indication as the makers state them

Compare a printed dimension, not an installation permission. Equal width does not establish a listed or classified combination.

Eaton CH3/4 in. per poleE5 p.5
Eaton BR1 in. per poleE5 p.5
Eaton CL1 in. per poleE12 p.103
Eaton CHQ3/4 in. per poleE5 p.8
Square D QO3/4 in. per poleQ7 p.67
Square D Homeline1 in. per poleQ7 p.67
Siemens QP1 in. per poleS9 p.1
Siemens QD3/4 in. per poleS9 p.47
GE / ABB THQL1 in. per poleG1 p.1
GE / ABB THQP1/2 in. per poleG1 p.1
Original drawing and source annotations

The original drawing is schematic, not a product label, field measurement or installation instruction.

Open the original full-size SVG

"½" THQP"; ABB not accepting new orders as of October 2, 2024

Sources: E5 Eaton Residential Product Guide MZ00400002E p.5, p.8; K5 Eaton KB 000015509; E12 Eaton CA08100002E (2022) p.103; E1 Eaton IL00304001Y p.1; Q6 Square D 0730CT9801 p.3;

Q7 Square D 1100CT0501 pp.45, 67; S9 Siemens SPEEDFAX SF-17 pp.1, 47; S4 Siemens QD brochure p.1; G1 ABB THQP notice (June 28, 2024) p.1. The panel label governs.

Two fictional breaker-like housings each with a separate blank document folder.
AI-generated concept illustration. Keep each family’s source statement separate. These generic objects do not depict Siemens, GE, Eaton or Square D products or establish an interchangeability claim. Not technical evidence.

Siemens compatibility table

PanelEraBreaker familySourceLimits / notes
Siemens load centerscurrentQP (10,000 A IR), QPH (22,000 A IR), HQP (65,000 A IR); AFCI/GFCI variants such as QAF2, QPF2, QFGA2, QE[S6 PDF p.35–36]Interrupting ratings per [S6 PDF p.36]
Panels manufactured before 1968legacyCertain QT space-saver breakers marked Non-CTL[S6 PDF p.37]Footnote: "For replacement use only in panels manufactured before 1968". See the CTL question in the FAQ
ITE/Siemens panelboards and Siemens meter centers on Eaton's listcurrent and legacyEaton CL (replaces Q115–Q250); CL115GFT–CL130GFT (replaces QF115–QF130); CL115AF–CL120AF (replaces Q115AF–Q120AF); CL115CAF–CL120CAF, CLCAF115–CLCAF120, CLAF115 and CLAF120 (replace Q115AFC–Q120AFC); CLDF115–CLDF120 (replaces Q115DFP–Q120DFP)[E1 p.4; panel lists pp.3, 5–7]E1 p.1: "Single-Phase, 3-Wire, 120/240 V~", "Max. Available Short Circuit Current 10 kAIC"; E1 p.4 DANGER: "Do not use in series rated systems with those panelboards shown in this compatibility list" [E1 p.1, p.4]. Eaton's 2026 brochure prints some replaced numbers differently (QF115AFC, Q115DF) [E3 p.3]
Murray Meter Combo, EQ Small Circuit, Rock Solid load centersmanufactured after January 2002Siemens equivalents of Murray types[S1 p.1–2]S1 p.1: "All Murray Meter Combo Load Centers, EQ Small Circuit Load Centers, and Rock Solid Load Centers manufactured after January 2002 may use Siemens brand circuit breakers." "Siemens brand circuit breakers are UL listed for use with the Murray products manufactured after that date."
Square D QO load centers on the QD listcurrent and legacySiemens QD (D115–D160 1-pole; D215–D260 2-pole)[S6 PDF p.39] [S4]Not series rated with Square D equipment; 10,000 A IR max

How to read a Siemens panel label

Look for two things (diagram D1):

  1. The load center catalog number, for example the G-, W- or E-prefixed numbers in Siemens' recall and catalog tables [C3] [S6 PDF p.32–34].
  2. Any date code. For the 2010 recall, load-center date codes are stamped inside the metal box [C3]. For the 1986–87 I-T-E inspection program, CPSC says the load centers "can be identified by a five-digit code marked on the top of the wiring diagram label inside the door"; its example: "A product manufactured on September 24, 1986 bears the code J2486." [C10]

Then compare the catalog number against:

  • Eaton IL00304001Y (Classified CL) [E1].
Where your panel's own documents put the key facts

Keep the label and the document together.

Catalog numbers, breaker-type lists and dates are different fields. The actual label can use a different layout.

  1. Catalog number

    Record the complete identifier, including suffixes. Square D label samples, pp.33–34, 60

  2. Printed breaker types

    Keep the wiring-diagram label with the box label. Murray 4810366, p.1

  3. Date code

    Preserve the exact code when comparing an applicable notice. CPSC QO notice

Original drawing and source annotations

The original drawing is schematic, not a product label, field measurement or installation instruction.

Open the original full-size SVG

door of the panel" [C8]

Sources: Q7 = Square D catalog 1100CT0501 (06/2026) pp.33-34, 60 (label and wiring-diagram sample callouts); S10 = Murray/Siemens instructions 4810366 Rev. D pp.1-2; C10, C3, C8 =

CPSC recall notices (1988; 2010; 2022). The panel label and a licensed electrician decide what may be installed.

Series and era history

WhenEventSource
Before 1968Non-CTL breakers restricted to replacement use in panels made before 1968[S6 PDF p.37]
Aug–Oct 1986 (installed Sep 1986 – May 1987)Certain I-T-E load centers with date codes H2586–H3186, J0186–J3086, K0186–K2486 included in a free Siemens inspection program (announced 1988)[C10]
1996–1998Siemens/Murray 2-pole GFCI breakers sold March 1996 – April 1998 later recalled[C4]
January 2002Cut-off date in Siemens' Murray substitution letter[S1 p.1]
June–August 2010Breakers with date codes 0610/0710 recalled (spring clip)[C3]
2017SPEEDFAX 2017 catalog edition used on this page[S6]
5 September 2019Siemens announces the Murray brand phase-out[S2 p.1]

Recalls and counterfeits

  • 2010 spring-clip recall (CPSC recall no. 10-354).
    • About 2.2 million Siemens and Murray 15–50 A breakers, plus certain load centers and a meter combo [C3].
    • Breaker catalog numbers listed: Q115, Q120, Q130, Q215, Q230, Q250 (and Murray MP equivalents), breaker date codes 0610 or 0710 [C3].
    • Load centers and meter combo made June 23 – August 25, 2010 [C3].
    • Remedy per CPSC: contact Siemens for a free inspection by an electrician and a free replacement [C3].
  • 1988 I-T-E load center inspection program (CPSC release 88-091).
    • Siemens offered free inspection and correction of certain I-T-E brand load centers installed between September 1986 and May 1987, because some were made with components of an incorrect material that could cause overheating and malfunction [C10].
    • Date codes involved: H2586–H3186, J0186–J3086 and K0186–K2486, marked at the top of the wiring diagram label [C10].
    • CPSC says a label stamped "inspected lugs" means the load center has already been inspected and corrected if necessary [C10].
  • 1998 GFCI recall. About 144,000 Siemens- or Murray-branded 2-pole GFCI breakers, typically used with hot tubs and spas [C4].
  • Counterfeits. U.S. Immigration and Customs Enforcement (ICE) reported counterfeit breakers bearing marks including Siemens [O2].

Common confusions

  • "Siemens makes a breaker for every brand." The SPEEDFAX catalog describes Siemens QD and Murray MSQ as UL Classified for specific Square D load centers in place of QO [S6 PDF p.39, p.61].
  • "QP and QD are the same, just different sizes."
    • QD is a ¾-inch format, UL Classified for specific Square D load centers in place of QO [S6 PDF p.39].
    • QP / QPH / HQP sit in the cross-reference row "Full Size (1" per Pole) with INSTA-WIRE" [S1 p.2].
  • "Eaton BR is a Siemens replacement." Eaton's line for ITE/Siemens panels is CL, and only for panels on its list [E1] [E3 p.3] [K4].

FAQ

Can I put a Square D breaker in a Siemens panel? Square D states its QO breakers are only UL tested and approved for QO, NQO, NQOD and NQ panelboards [Q3], and that Homeline breakers are not classified for competitors' load centers [Q2].

Will Eaton breakers work in a Siemens panel? Eaton's IL00304001Y prints Siemens meter centers under Type CL headings [E1 p.3] and ITE/Siemens panelboards on pp.5–7; the Eaton type heading printed there is "CLDF115, CLDF120" [E1 p.5]. The limits are 120/240 V and 10 kA [E1 p.1], and the list must not be used for series-rated systems [E1 p.4].

Are Siemens and Murray breakers the same? Siemens says Siemens and Murray meter combos, EQ Small Circuit load centers and breakers are "typically identical in construction and only differ in labeling" [S2 p.1]. Use in a given panel still follows the label and the January 2002 letter [S1 p.1].

What does Non-CTL mean on a Siemens breaker? Siemens' catalog footnote says Non-CTL breakers are for replacement use only in panels manufactured before 1968 [S6 PDF p.37]. Eaton's catalog explains the background. It says: "National Electrical Code Paragraph 384.15 requires branch circuit panelboards to be provided with physical means to prevent the installation of more overcurrent devices than that number of which the enclosure was designed, rated and approved." [E12 p.V1-T1-91] Eaton's Class CTL duplex, quadplex and twin breakers carry a UL listed rejection tab, and versions made without the tab are "available for replacement purposes in older interiors" [E12 p.V1-T1-91]. Eaton describes its own Non-CTL BRD breakers as "For replacement in enclosures manufactured prior to 1968 with unnotched stabs" [E12 p.V1-T1-78]. This is Eaton's wording.

What is a Siemens QD breaker? A ¾-inch breaker, UL Classified and UL Listed, for use in place of Square D QO breakers in the Square D load centers on its Panelboard Compatibility List [S6 PDF p.39].

Sources

IDPublisherDocument / versionLinkKind
E1EatonIL00304001Y, visible imprint "Revised September 2024" (p.10); hidden text layers also contain "Revised May 2024" and REV. 24/27 markers; PDF mod 2025-06-05, 10 pplinkprimary
E3EatonBR003051EN (URL br003034en), July 2026, 4 pplinkprimary
E12EatonCA08100002E Volume 1 Residential and Light Commercial, November 2022, full 105 pp (PDF created 2022-11-02); captured 2026-11-15linkprimary
K4Eaton Knowledge HubArticle 000011287 "Eaton replacement circuit breaker that fits in a Siemens loadcenter", printed 2026-11-15linkprimary
S1Siemens Industry (copy linked from the Siemens Sandy FAQ page S3)letter dated 2019-09-05, 2 pplinkprimary-mirror
S2Siemens Industry (copy linked from the Siemens Sandy FAQ page S3)letter dated 2019-09-05, 2 pplinkprimary-mirror
S4Siemens (cache.industry.siemens.com)SIE_BR_QD (PDF mod 1999-06-05), 2 pplinkprimary
S6Siemens IndustrySPEEDFAX 2017 Section 1 Load Centers & Circuit Breakers (PDF mod 2020-02-13), 66 pplinkprimary
Q2Schneider Electric / Square DFAQ FA129931, fetched 2026-11-15linkprimary
Q3Schneider Electric / Square DFAQ FA124299, fetched 2026-11-15linkprimary
P3UL Solutions Product iQ (abridged, no login)Profile DIVQ.E82615, captured 2026-11-15linkprimary
C3U.S. CPSCrecall 2010-09-23linkprimary
C4U.S. CPSCrecall 1998-10-07linkprimary
C10U.S. CPSCcpsc.gov recall web page, Recall Date November 01, 1988, recall number 88-091; printed to PDF in browser 2026-11-16, 4 pplinkprimary
O2U.S. ICEnews release (case 2010)linkprimary

All documents fetched 2026-11-15 or 2026-11-16 and archived with SHA256 (see SOURCE-LIBRARY.csv). Kind: primary = issued by the manufacturer/agency; primary-mirror = manufacturer document hosted by a third party.

Keep the reference with your question.

Retain the exact identifier, document revision, page and unresolved conditions. The lookup covers only one Eaton list; a result is not an equipment or installation assessment.

Search Eaton’s document Record a source discrepancy